Art-Nr.: 57614
EASKD 31.5 2U 3x600-300/5A 10-5VA Kl.0,5 - Billing current transformer
The EASKD 31.5 2U 3x600-300/5A 10-5VA Kl.0,5 is a compact, high-precision billing current transformer of the proven EASKD series that can be switched between two primary currents, specially developed for use in power distribution, switchgear, meter panels and industrial measurement and monitoring systems.
Technical main features:- Type Billing current transformer (busbar type) – EASKD
- Transformation ratio 3x600-300/5 A (primary rated currents 600 A and 300 A, secondary rated current 5 A)
- Rated power / burden 10–5 VA
- Accuracy class Kl. 0,5 (according to IEC/EN 61869-2 or DIN EN 61869-2)
- Primary conductor bore For busbar 31.5 mm thick, 2U high (approx. 70 mm)
- Maximum operating voltage Um ≤ 0.72 kV
- Rated frequency 50–60 Hz
- Thermal rated continuous current Icth = 1.2 × Ipr (continuous current 1.2 × primary rated current)
- Thermal rated short-time current Ith = 100 × Ipr, 1 s
- Insulation class E
- Insulation test voltage 3 kV, 50 Hz, 1 min
- Dimensions (approx.) Depending on configuration, typical for busbar mounting
- Weight (approx.) 1.5–2.5 kg (depending on version)
- Mounting Direct busbar fastening, including secondary terminals
The EASKD 31.5 2U 3x600-300/5A 10-5VA Kl.0,5 stands out for its robust busbar adaptation, high reliability and excellent accuracy – ideal for applications where precise billing and measurement are required at higher currents (e.g. larger distribution boards, switchgear, energy monitoring systems with high power requirements).
We are happy to supply this model from stock at short notice or configure further variants of the EASKD series for you.
Contact us for your individual quote!
3D models and more files to each product can be found in our download area downloadarea
current transformer knowledge
Background knowledge on the selection, dimensioning and technical parameters of current transformers – prepared in a practical manner.
Read morecurrent transformer correctly select & dimension
Published on 10 July 2026 · Updated on 31 July 2026
The choice of the suitable current transformer depends on primary current, connection values and purpose of use. This guide leads step by step through the most important selection criteria.
Read moreAccuracy classes for current transformers explained
Published on 10 July 2026 · Updated on 31 July 2026
What do specifications like class 0,5 or 0,2s mean for a current transformer? An overview of the common accuracy classes and their areas of application.
Read moreStromwandler richtig anschließen
Published on 24 September 2026 · Updated on 25 September 2026
Ein Stromwandler misst nur dann richtig, wenn er in der richtigen Richtung eingebaut und sekundärseitig korrekt verdrahtet ist. Entscheidend sind drei Punkte: Die Primärklemme P1 (K) zeigt zur Einspeisung, die Sekundärkl…
Read more