Measurement of currents at isolated inputs (TRMS)
Via CT, primary side 9,999 A
Via CT, secondary side 1 or 5 A
measuring range 0 … 11 kA
Consumption of the inputs ≤ 0,1 VA
Update frequency of the measured value 1 s
Accuracy 0,2%
Continuous overload 6 A
Short-time overload 10 In for 1s

Voltage measurement (TRMS)
Direct measurement between phases 50 ... 500 VAC CAT.II /
1040 VAC CAT.III
Direct measurement between phase and neutral conductor 28 ... 289 VAC CAT.III /
600 VAC CAT.II
VT measurement via voltage transformer, primary side 500 000 VAC
VT measurement via voltage transformer,
secondary side
60, 100, 110, 173, 190 VAC
Frequency 50/60 Hz
Consumption of the inputs ≤ 0,1 VA
Update frequency of the measured value 1 s
Accuracy 0,2 %

Product current - voltage
Limit value for CT 1 A 10.000.000
Limit value for CT 5 A 10.000.000

Power measurement
Update frequency of the measured value 1 s
Accuracy 0,5 %

Power factor measurement
Update frequency of the measured value 1 s
Product information

The Multifunctional measuring and monitoring device A-41 is a digital measuring device for the reliable monitoring of electrical parameters in control cabinets and distributions.

Technical main features:
  • Type number A-41

Due to its versatile functions, the device is ideally suited for permanent measurement and monitoring in industrial plants and distribution cabinets.

We would be happy to advise you on suitable versions and accessories for your application.

Contact us for your individual offer!

Properties
Dimension (BxHxT mm): 96 x 96 x 60
Display: LCD (backlit)
Type-Name: DIRIS
ambient temperature: -10 - +55 °C
protection rating: Front side IP 52, Housing IP 30
storage temperature: -20 - +85 °C
Weight: 0.4 kg
Width: 96 mm
Height: 96 mm
Length: 60 mm
Measurement of currents at isolated inputs (TRMS)
Via CT, primary side 9,999 A
Via CT, secondary side 1 or 5 A
measuring range 0 … 11 kA
Consumption of the inputs ≤ 0,1 VA
Update frequency of the measured value 1 s
Accuracy 0,2%
Continuous overload 6 A
Short-time overload 10 In for 1s

Voltage measurement (TRMS)
Direct measurement between phases 50 ... 500 VAC CAT.II /
1040 VAC CAT.III
Direct measurement between phase and neutral conductor 28 ... 289 VAC CAT.III /
600 VAC CAT.II
VT measurement via voltage transformer, primary side 500 000 VAC
VT measurement via voltage transformer,
secondary side
60, 100, 110, 173, 190 VAC
Frequency 50/60 Hz
Consumption of the inputs ≤ 0,1 VA
Update frequency of the measured value 1 s
Accuracy 0,2 %

Product current - voltage
Limit value for CT 1 A 10.000.000
Limit value for CT 5 A 10.000.000

Power measurement
Update frequency of the measured value 1 s
Accuracy 0,5 %

Power factor measurement
Update frequency of the measured value 1 s