Art-Nr.: WMDEPAT10
Sonel PAT-10 Portable Appliance Tester
| Parameter | Specifications |
|---|---|
| Visual inspection | √ |
| Protective conductor resistance I = 200 mA | 0,01…19,99 Ω |
| Protective conductor resistance I = 10 A | 0,01…1,99 Ω |
| Insulation resistance U = 250 V | 0,25…99,9 MΩ |
| Insulation resistance U = 500 V | 0,50…99,9 MΩ |
| Substitute leakage current | 0,01...19,9 mA |
| Touch current | 0,001…4,999 mA |
| Protective conductor current (residual current) | 0,10…19,9 mA |
| IEC extension (RISO, RPE, polarity) | √ |
| PRCD (tripping time for IΔn: x1/x5; 0° and 180°) | 10 mA, 30 mA |
| Internal test data memory / data transfer to PC | √ |
| Wi-Fi | √ |
| Connection to printer | √ |
| Measuring device configuration from the computer | √ |
| Power supply | Mains power supply: 220 V; 230 V; 240 V 50/60 Hz Battery supply |
| Measurement category | CAT II 300 V |
Sonel PAT-10 – Compact Tester for Electrical Appliances and Cables
The Sonel PAT-10 combines high measurement performance with maximum mobility. Thanks to its compact design and low weight, it is perfectly suited for on-site use – whether in workshops, on construction sites or for recurring safety tests. All important measurements can be started at the touch of a button, carried out fully automatically and individually configured if required.
Fully automatic test sequences & flexible measurement modes
Whether electrical appliances, IEC cables or extension cables with PRCD – the PAT-10 reliably tests in accordance with relevant standards such as VDE 0701-0702 or EN 50699. In addition to automatic complete tests, a manual mode is also available for individual tests. In battery operation, simplified tests can also be carried out without an external power supply.
Functions at a glance
- LED result display and quick-start buttons
- Automatic measuring range selection
- Protective conductor test with 200 mA or 10 A
- Insulation measurement at 250 V or 500 V
- PRCD trip time test
- Leakage current, touch current and residual current measurement
- Extension and mains voltage test
- Memory for measurement results & optional label printing
- Software connection for PC and mobile devices
Ergonomics & data management
The specially developed housing and the ergonomic carrying bag ensure comfortable handling. Via the integrated wireless interface, test protocols can be sent directly to a compatible printer – without annoying cables. The measurement results can be stored in the internal memory and subsequently processed, evaluated and documented with the Sonel PAT Analysis or the PAT Analysis Mobile App.
Areas of application
The Sonel PAT-10 is ideal for electrical companies, test service providers, industrial companies and landlords of electrical appliances. Thanks to standard compliance and flexible test modes, it is suitable for both regular repeat tests and tests after repair or modification.
Conclusion: With the Sonel PAT-10 you get a robust, mobile test device that combines ease of use, precision and extensive test options in one compact system – perfect for anyone who wants to test electrical equipment safely and in compliance with standards.
| Properties |
|---|
| Display: | LED |
|---|---|
| Humidity max.: | 80% |
| interface: | USB 2.0, WiFi |
| measurement category: | CAT II 300 V |
| operating temperature: | 0 °C - +50 °C |
| power supply: | 220 VAC, 230 VAC, 240 VAC |
| protection rating: | Enclosure IP 40 |
| storage temperature: | -20 - +70 °C |
| Weight: | 1.4 kg |
| Width: | 180 mm |
| Height: | 77 mm |
| Length: | 200 mm |
| Parameter | Specifications |
|---|---|
| Visual inspection | √ |
| Protective conductor resistance I = 200 mA | 0,01…19,99 Ω |
| Protective conductor resistance I = 10 A | 0,01…1,99 Ω |
| Insulation resistance U = 250 V | 0,25…99,9 MΩ |
| Insulation resistance U = 500 V | 0,50…99,9 MΩ |
| Substitute leakage current | 0,01...19,9 mA |
| Touch current | 0,001…4,999 mA |
| Protective conductor current (residual current) | 0,10…19,9 mA |
| IEC extension (RISO, RPE, polarity) | √ |
| PRCD (tripping time for IΔn: x1/x5; 0° and 180°) | 10 mA, 30 mA |
| Internal test data memory / data transfer to PC | √ |
| Wi-Fi | √ |
| Connection to printer | √ |
| Measuring device configuration from the computer | √ |
| Power supply | Mains power supply: 220 V; 230 V; 240 V 50/60 Hz Battery supply |
| Measurement category | CAT II 300 V |