CCT 41.4 I - Allstromwandler AC/DC
| Measuring range | 0…500 A DC / AC Ieff, variant-dependent! (Rated current ranges set to standard values acc. to IEC) |
| Frequency range | 0…100 kHz, any signal waveforms |
| Current output for AC input signal: | AC: 0…20 mA Ieff, (± 28,2843 mA IPeak) |
| Current output for DC input signal | DC: 0…± 20 mA |
| Max. burden resistance at current output | RB ≤ 300 Ω (UH = 24 V DC) |
| Output signal limitation in case of overload | < 25 mA |
| Accuracy | ± 0,5 % |
| Max. operating voltage Um | 0,72 kV, Ueff |
| Insulation test voltage | 6,4 kV, Ueff, 50 Hz, 5 sec., Primary conductor against measuring output/housing |
| Auxiliary voltage | ± 12 V DC, ± 15%, < 70 mA, external protection via fine fuse 100 mA / 250 V, fast! |
| Step response time (90 % IPN, di/dt = 100 A / μs) | ≤ 1 μs (typ. 150 ns) |
| Signal rise rate di/dt | < 100 A / μs |
| Insulation material class | E |
| Operating altitude | ≤ 2000 m (DIN EN 61010-1) |
| Max. temperature of the primary conductor | 100° C |
| Humidity | 0…95% rel. humidity, no condensation! |
Product information
Current transformer for measuring both direct and alternating currents
- For use in network analysis
- and for current measurement of non-sinusoidal and distorted networks
Applied technical standards:
DIN EN 50178, 1997
DIN EN 61010-1, 2002
VDE 0160
Electrical connections:
UH + UH - 0 (Ground) IA
Spring-loaded terminal
Connection cross-sections: 0,08…2,5 mm²
Functions of the CCT 41.4 I:
- The magnetic field surrounding a current-carrying conductor is detected by a measuring core enclosing the conductor. The magnetic flux induced in the measuring core, which is directly proportional to the current in the primary conductor, is detected by means of a semiconductor component. Integrated control electronics in the device convert the signal supplied by the semiconductor into an output current signal directly proportional to the time profile of the measured variable.
- The inductive, contactless detection of the measured variable provides a galvanically isolated output signal.
- The electrical contacting of the secondary circuit of the current transformer is carried out via a 4-pole spring-loaded terminal. This terminal is suitable for connecting flexible stranded wires up to 2,5 mm².
- A DC auxiliary power supply of ± 12 V is required to supply the control electronics. The auxiliary voltage inputs must be protected by a 100 mA / 250 V / F fine fuse.
Advantages and benefits of the CCT 41.4 I:
- Measurement of both direct and alternating currents possible with only one transformer.
- Wide operating frequency range from 0 Hz (DC)…100 kHz (AC).
- High electrical safety due to galvanically isolated detection of the measured variable.
- Low power requirement (≤ 2,5 VA)
- Simple and safe electrical wiring using spring-loaded terminal technology.
- Direct mounting on busbars via fastening screws integrated in the device.
- Mounting on 35mm DIN rails possible using optional snap-on mounting.
- High climatic and mechanical resistance due to PU encapsulation of all electrical components.
3D models and more files to each product can be found in our download area downloadarea
| Properties |
|---|
| Output: | 0 - +/- 20 mA DC, 0 - 20 mA AC (left) |
|---|---|
| Type-Name: | CCT |
| Type number: | 41.4 I |
| ambient temperature: | -25 - +60 °C |
| auxiliary voltage: | 12 - 15V DC |
| bore: | Ø 31,95 mm |
| storage temperature: | -40 - +90 °C |
| Width: | 90 mm |
| Height: | 115 mm |
| Length: | 58.5 mm |
| Measuring range | 0…500 A DC / AC Ieff, variant-dependent! (Rated current ranges set to standard values acc. to IEC) |
| Frequency range | 0…100 kHz, any signal waveforms |
| Current output for AC input signal: | AC: 0…20 mA Ieff, (± 28,2843 mA IPeak) |
| Current output for DC input signal | DC: 0…± 20 mA |
| Max. burden resistance at current output | RB ≤ 300 Ω (UH = 24 V DC) |
| Output signal limitation in case of overload | < 25 mA |
| Accuracy | ± 0,5 % |
| Max. operating voltage Um | 0,72 kV, Ueff |
| Insulation test voltage | 6,4 kV, Ueff, 50 Hz, 5 sec., Primary conductor against measuring output/housing |
| Auxiliary voltage | ± 12 V DC, ± 15%, < 70 mA, external protection via fine fuse 100 mA / 250 V, fast! |
| Step response time (90 % IPN, di/dt = 100 A / μs) | ≤ 1 μs (typ. 150 ns) |
| Signal rise rate di/dt | < 100 A / μs |
| Insulation material class | E |
| Operating altitude | ≤ 2000 m (DIN EN 61010-1) |
| Max. temperature of the primary conductor | 100° C |
| Humidity | 0…95% rel. humidity, no condensation! |