Art-Nr.: 0053944
Belastungswächter BH 9097.38/001
Load monitor for monitoring electrical industrial drives for symmetrical loading of all three phases. It monitors the active power consumption of motor loads.
Features
- according to IEC/EN 60 255, DIN VDE 0435-303
- Detection of underload P1, overload P2, overload P1 (pre-warning stage) and overload P2 (switchable)
- Setting of P1 and P2 via absolute scale
- for motors up to 22 kW / 400 V or 37 kW / 690 V
- Measuring method: active power measurement
- wide current measuring range thanks to automatic range switching
- 1 changeover contact each for signalling P1 and P2
- adjustable start-up override ta
- adjustable pickup delay tv
- with or without latching, switchable
- Test / reset button for easy commissioning and as setting aid
- up to 40 A without external current transformer
- Energized on trip principle (output relay activated in case of fault) or de-energized on trip principle (output relay not activated in case of fault)
- Switchable optionally for 1-phase loads LED indicators
- 45 mm overall width
Application
The load monitor is suitable for monitoring electrical industrial drives with variable motor load. Design and function: The load monitor BH 9097 monitors the active power consumption of electrical loads. Due to the 1-phase measuring principle, symmetrical loading of all 3 phases is assumed, as is usual with motor loads. Using DIP switches, the device can be configured as an underload and overload monitor P1 min / P2 max. or as an overload monitor with pre-warning stage P1 max. / P2 max. The settings for P1 and P2 are calibrated as absolute values in watts and are made via two rotary switches. 2 LEDs indicate the switching state of the associated output relays. The relays can be configured for energized on trip or de-energized on trip principle. Each relay is subject to a separately adjustable pickup delay tv and a jointly adjustable start-up override ta.
Measuring current (see table): A, C, E
| Measuring range | A | B | C | D | E | F |
|---|---|---|---|---|---|---|
| Rated current A | 40 | 24 | 8 | 2,4 | 0,8 | 0,24 |
| Continuous overload | 0...40 | 0...40 | 0...16 | 0...8 | 0...4 | 0...1 |
| Overload 1 min. (10 min. pause) | 150 |
| Properties |
|---|
| Dimension (BxHxT mm): | 45 x 84 x 121 |
|---|---|
| Phases: | 3-phase without supply voltage |
| Type-Name: | BH |
| Type number: | 9097.38/001 |
| ambient temperature: | -20 - +55 °C |
| measuring voltage: | 400 VAC |
| protection rating: | Enclosure IP 40, Terminals IP 20 |